PDP-8 Specification and Profile Contract
Configuration
machine_model: named PDP-8 variant or explicit abstract profile.memory_words: configured word count, bounded by the selected model and installed options.extended_arithmetic: enables EAE behavior only where supported.memory_extension: enables fields and instructions only where supported.io_devices: explicit device registry and IOT handlers.strict_profile: reject unsupported operations by default.
Word and address model
The base architecture uses 12-bit words and a 12-bit program counter/address. Mask values at architectural boundaries. Larger memory configurations require the appropriate documented memory-extension model rather than silently widening addresses.
Execution contract
- Fetch one 12-bit instruction from configured memory.
- Decode the instruction group and fields according to the selected profile.
- Resolve page and indirect addressing with documented auto-index behavior.
- Apply arithmetic and link-bit semantics at 12-bit width.
- Route IOT operations to configured device handlers.
- Report illegal or unsupported operations through structured diagnostics.
Optional facilities
Extended arithmetic, memory extension, and device behavior are not universal across every PDP-8 configuration. Keep option-specific state and instructions disabled unless selected.
Safety
Validate every memory reference against installed memory and active fields. Never treat a guest address as an unchecked host-memory index.